Roof Ventilation and Sarking

Whirlybirds, vents and sarking, matched to the real problem.

$0 CALLOUT FEE IN BUSINESS HOURS | FREE QUOTES | SAME DAY SERVICE

Google

Overall Rating

4.9

Five stars

(3,000+)

Brightest & Best Business Awards: Winner 2019, Winner 2024, Winner 2025, People's Choice 2025, Finalist 2023

NOW SERVICING NORTH SYDNEY

  • 35+ Years of Combined Experience
  • Yes, a Real Plumber Reads These Messages Too
  • The Kettle Is Always On at Head Office
  • $0 Call Out Fees
  • Every Job Photographed, Every Price Upfront
  • We Answer the Phone. Revolutionary, We Know.
  • Trusted by 15,000+ Sydney Families
  • No Call Centres. You Get a Human in Sydney
  • Your Neighbours Probably Have Our Fridge Magnet
  • Onsite in 30 Minutes Guaranteed
  • Boots Off at the Door. Every Single Time.
  • 3,000+ Google Reviews and Counting
  • In the community For the community

THE SHORT ANSWER

In short

Roof ventilation lets moist and hot air out of the roof space. We install whirlybirds, ridge, eave and soffit vents, and sarking under tiles, and we tell you straight when ventilation will help and when insulation, sealing the ceiling or fixing a fan that vents into the roof will do more. $0 call-out Monday to Friday, 7:00am to 3:00pm, and Saturday, 7:00am to 12:00pm. Outside those times, and all day on NSW public holidays, the call-out fee is $385 ($350 plus GST), paid before we send a plumber.

Licensed & Insured (NSW 285594C)

24/7 Emergency

$0 Call-Out in Business Hours

Upfront Fixed Pricing

Lifetime Labour Warranty

Family Owned

SIGNS OF A MOISTURE PROBLEM

Condensation and mould: sign, cause and fix

What you noticeLikely causeWhat helps
Drips from the ceiling or downlights on cold, clear mornings, with no rainCondensation forming on the underside of a metal roof and dripping onto the ceilingA vapour-permeable membrane under the roof that drains condensation outside, plus ventilation
Mould along cornices and on ceilings near outside wallsMoist indoor air meeting cold surfacesExhaust fans that vent outside, sealing gaps in the ceiling, and insulation
Mould or black spots on the bathroom ceilingNo exhaust fan, or one that vents into the roof spaceDuct the fan outside, sized to the building code
Damp or matted insulation, or rusty nails and fixings in the roof spaceCondensation forming in the roof space again and againFind and stop the moisture source, then ventilate
A musty smell from the manholeMoisture building up in a roof space with little airflowHave the roof space inspected for its moisture source and airflow
Water stains that appear only after rainA roof leak, not condensationSee roof leak repairs

Condensation can form on the underside of any roofing material, in any climate zone, whenever the surface drops below dew point; good practice drains it to the outside of the building (YourHome).

WHY VENTILATE

What roof ventilation does

Condensation can form under any roof, in any season, whenever the underside drops below dew point (YourHome). As homes have become more airtight, roof spaces have been sealed up and condensation risk has risen; a well-ventilated roof space carries the water vapour out and helps prevent mould (YourHome).

Ventilation also lets hot air out of the roof space in summer. But most heat reaches a ceiling as radiation from the roof itself, which insulation, foil sarking and a lighter roof handle better (YourHome).

THE OPTIONS

Whirlybirds, vents and fans

We found no independent Australian test comparing them, so we don’t promise energy savings. We match the option to the problem.

Whirlybirds

Wind-driven turbines near the ridge that draw air out of the roof space. No power needed; they work best with intake vents low down at the eaves.

Ridge, eave and soffit vents

Openings low and high in the roof so air flows through it. These are the methods BlueScope lists for ventilating metal roofs (SteelSelect).

Powered and solar fans

Fans that pull air out on demand. A US study found solar roof fans cut roof-space temperature a lot but air-conditioning energy only about 6 percent, with a payback over 20 years (Florida Solar Energy Center).

SIDE BY SIDE

Whirlybirds, static vents and powered fans compared

WhirlybirdStatic ridge and eave ventsPowered or solar fan
Needs powerNoNoYes, mains or a solar panel
Works whenThe wind blows, and as warm air risesAll the time, by natural air movementWhenever it runs, wind or not
Moving partsA spinning turbine on bearings that wearNoneA motor
Best forDrawing air out high on a pitched roof, with intake low downSteady background airflow right through the roof spaceMoving a set amount of air on demand
Watch out forToo little intake, so it draws air up from the houseOpenings that need ember protection on bushfire-prone landRunning cost, and drawing moist indoor air up through an unsealed ceiling

Whatever goes out at the top has to come in somewhere. Without intake vents low down at the eaves, any exhaust device pulls its air from the rooms below, through downlights, manholes and gaps at the cornice, and that can carry more moisture into the roof space, not less.

THE BUILDING CODE

Does the building code require roof ventilation?

Since 1 October 2023 the NCC’s condensation rules apply in NSW. The roof-space ventilation rule (Housing Provisions 10.8.3) applies only in climate zones 6, 7 and 8 (NCC 2022 Part 10.8). Coastal Sydney is zone 5; the hinterland west of Sydney is zone 6 (YourHome).

The rule applies to new building work. It does not require existing roofs to be upgraded, but the same principles apply when you renovate or re-roof.

One rule applies everywhere: bathroom, kitchen and laundry exhaust fans must discharge outside, not into the roof space.

THE CODE IN DETAIL

What the NCC condensation rules actually say

The ABCB’s Housing Provisions Part 10.8, condensation management, has three clauses. They apply to new building work, and they are a sensible benchmark when you renovate or re-roof (ABCB Housing Provisions Part 10.8).

10.8.1 Wall membranes

Where a pliable membrane goes on the outside of the wall insulation, it must meet AS 4200.1, be installed to AS 4200.2, and let enough water vapour through for the climate: at least 0.143 µg/N.s in climate zones 4 and 5 (coastal Sydney is zone 5), and more in colder zones. Class 3 and Class 4 membranes meet the zone 4 and 5 figure.

10.8.2 Exhaust fans

  • Minimum flow rates: 25 litres a second for a bathroom or toilet, and 40 litres a second for a kitchen or laundry
  • Kitchen, range hood, bathroom, toilet and laundry exhaust must discharge to outdoor air, directly or through a duct
  • A vented clothes dryer must discharge to outdoor air as well
  • A bathroom fan that does not run all the time must switch on with the light and keep running for 10 minutes after the light goes off
  • Replacement air must be able to get in: a 20 mm gap under a 700 mm wide door meets the code’s opening size

10.8.3 Roof space ventilation

In climate zones 6, 7 and 8, the roof space must have a gap of at least 20 mm above the insulation or permeable sarking, ventilated through evenly spread openings. For a roof pitched between 15 and 75 degrees, that is 7,000 mm² per metre at the eaves and 5,000 mm² per metre high up, at or near the ridge. An unsarked tiled roof already counts as ventilated.

Summarised from NCC 2022 Housing Provisions Part 10.8. NSW adopts NCC 2025 on 1 May 2027 (NSW Government).

SARKING

What’s under your tiles: sarking

Sarking is the membrane laid under tiles or metal sheets to catch wind-driven rain and dust, and foil sarking also reflects heat. Under the NCC, sarking under tiles must meet AS 4200.1, every tiled roof flatter than 18 degrees must be sarked, and steeper roofs need it over longer rafter runs (NCC 2022 Part 7.3).

Membranes are graded by how much water vapour they let through: Classes 1 and 2 hold it in, Classes 3 and 4 let it out, which is better for condensation (YourHome). Foil needs an air gap of at least 20 mm next to its shiny side to work, and must not touch electrical cables (YourHome).

WHEN IT WON’T HELP

When more ventilation won’t help

  • A bathroom, kitchen or laundry fan venting into the roof space: duct it outside first (YourHome)
  • Gaps around downlights, manholes and ceiling edges letting moist air up into the roof: seal the ceiling
  • Loose ceiling insulation with air blowing through it, which makes the insulation work less well
  • A hot house in summer from radiant heat: insulation, foil sarking or a lighter roof colour do more
  • An unsarked tiled roof, which already breathes through the gaps between the tiles

MOULD

Mould on the ceiling: what to do

Mould spores can cause a runny or blocked nose, irritated eyes and skin, and sometimes wheezing, and can trigger asthma attacks (NSW Health).

  1. Fix the moisture first. Mould comes back if the water does. NSW Health lists leaking roofs, blocked gutters and plumbing leaks among the problems to repair.
  2. Clean small areas on hard surfaces with a mild detergent or a vinegar solution, 4 parts vinegar to 1 part water, then dry the surface completely. NSW Health suggests diluted bleach only for stubborn mould, with protective gear and good ventilation.
  3. Run exhaust fans when showering, cooking, doing the laundry and drying clothes, and open windows when the weather allows.
  4. Renting? Tell your landlord or agent in writing. NSW Fair Trading is on 13 32 20.
  5. Health worries? See your doctor; in an emergency, call 000.

WHAT YOU CAN CHECK

Checks you can do without going into the roof

  • Hold a sheet of toilet paper near each exhaust fan grille while it runs. If it barely moves, the fan is weak, blocked or poorly ducted.
  • From the manhole, with a torch, look for where each fan duct ends. A duct that stops in the roof space, or a fan with no duct, is venting moist air into the roof.
  • Look for gaps around downlights, the manhole cover and the cornices, which let moist air up.
  • Note when the water appears: in rain, or on cold, clear mornings. That tells us leak or condensation.
  • Don’t walk across the ceiling joists. A foot through the plaster is a common injury and an expensive repair. Leave the roof space to us.

WHO DOES THE WORK

Licensed for roof ventilation

In NSW, installing ventilators is roof plumbing work, which our licence (285594C, Roof Plumber class) covers (NSW Government). Depending on the size of the job, the work is done by our own team or by a licensed partner we manage. Your written contract names who does the work and the licence they hold, and our lifetime labour warranty covers it either way.

REVIEWS BY PROBLEM

What your neighbours say

Real reviews from our customers across Sydney, in their own words. Read every review, good and bad, on Google.

Repairs

Plumbing repair

“From scheduling an appointment to the actual repair, everything was seamless and efficient. Our plumber, Jack, was professional, knowledgeable and went above and beyond to ensure our issue was fixed to our satisfaction. The team provided us with a clear explanation of the problem and the solution, and we appreciated their honesty and transparency.”

Plumbing repair

“I was very impressed with the service I received from Proximity Plumbing. The technician was prompt, knowledgeable, and professional. He quickly diagnosed the issue and provided me with a clear explanation of the problem and the solution. The repair was completed efficiently and at a reasonable price.”

General plumbing

“I found Proximity Plumbing online and made contact. Immediately I was contacted and we discussed the job. I was passed onto the plumber that would be doing the work. Communication was excellent. The plumber arrive exactly on time and was professional and efficient.”

Hot water

Hot water installation

“Proximity Plumbing provided excellent customer service and professional workmanship when installing a new hot water system in my home. The team was prompt, friendly and took the time to explain the installation process and answer any questions I had. I was impressed with their attention to detail and cleanliness during the job, leaving my home just as they found it.”

Leaks

Leaking tap repair

“I recently used Proximity Plumbing for a leaky faucet repair and was extremely satisfied with their service. The technician arrived on time, was professional and knowledgeable, and fixed the issue quickly. The pricing was fair and transparent, and I appreciated the follow-up call to make sure everything was working properly.”

Renovations

Bathroom renovation

“I had a wonderful experience working with Proximity Plumbing for my bathroom renovation. They were professional, knowledgeable and efficient. The team was great to work with and provided excellent advice and recommendations. The final result was exactly what I wanted, a beautiful and functional bathroom that I love spending time in.”

AT A GLANCE

Key facts

Service

Roof ventilation and sarking

Licence

NSW 285594C, Roof Plumber class

Since

2015

Contracts

Written contract over $5,000; HBC insurance over $20,000

Labour

Lifetime labour warranty

Call-out

$0 call-out Monday to Friday, 7:00am to 3:00pm, and Saturday, 7:00am to 12:00pm. Outside those times, and all day on NSW public holidays, the call-out fee is $385 ($350 plus GST), paid before we send a plumber.

Area

Eastern Suburbs, Inner East and Lower North Shore

QUESTIONS

Roof ventilation questions

EXPLORE

More roof services

SYDNEY ROOF PLUMBERS

Talk to a licensed roof plumber

We find the cause, show you photos and give you a fixed price before any work starts.

Licensed roof plumber, NSW 285594C

$0 call-out in business hours

Lifetime labour warranty

4.9 from 3,000+ reviews