Heat Pump Hot Water

The most efficient electric hot water, using heat from the air, with NSW discounts on eligible models.

$0 CALLOUT FEE IN BUSINESS HOURS | FREE QUOTES | SAME DAY SERVICE

Google

Overall Rating

4.9

Five stars

(3,000+)

Brightest & Best Business Awards: Winner 2019, Winner 2024, Winner 2025, People's Choice 2025, Finalist 2023

NOW SERVICING NORTH SYDNEY

  • 35+ Years of Combined Experience
  • Yes, a Real Plumber Reads These Messages Too
  • The Kettle Is Always On at Head Office
  • $0 Call Out Fees
  • Every Job Photographed, Every Price Upfront
  • We Answer the Phone. Revolutionary, We Know.
  • Trusted by 15,000+ Sydney Families
  • No Call Centres. You Get a Human in Sydney
  • Your Neighbours Probably Have Our Fridge Magnet
  • Onsite in 30 Minutes Guaranteed
  • Boots Off at the Door. Every Single Time.
  • 3,000+ Google Reviews and Counting
  • In the community For the community

THE SHORT ANSWER

In short

A heat pump works like a reverse air conditioner: it takes heat from the air and moves it into the water, using about 30% of the energy of a conventional electric system. With solar, it is usually the cheapest kind of hot water to run. It costs more to buy, about $3,800 to $6,650 installed in Sydney before discounts, and eligible models attract the NSW Energy Savings Scheme discount and federal STCs. The compressor makes a noise like an air conditioner, so where it goes matters.

HOW IT WORKS

Heat from the air, not from an element

A fan draws air over a coil filled with refrigerant. The refrigerant soaks up the air’s heat, a compressor concentrates it, and that heat warms the water in the tank. For every unit of electricity it uses, it delivers about 3 to 5 units of heat.

Integrated units have the compressor on top of the tank; split units put the noisy part separately, lower and up to 10 to 15 metres away (YourHome).

Some heat pumps are not compatible with off-peak controlled load power, and others only with Controlled Load 2, so we check your wiring and tariff before we recommend one.

A Proximity plumber talking with a customer in her kitchen

SIZES

Tank sizes by household

Heat pumps are sized by their tank in litres. Reece lists heat pumps from about 200 L to 340 L. One person uses about 50 litres of hot water a day.

Tank sizeSuits
200 to 220 LUp to about 4 people
270 to 285 LAbout 4 to 5 people
300 to 340 LAbout 5 to 6 people

Facts checked 1 November 2026. Sources: YourHome, energy.gov.au, Building Commission NSW and Rheem’s sizing guide.

RUNNING COSTS

How a heat pump saves power, and what eats into it

Efficiency is measured as a coefficient of performance (COP): the heat delivered to the water for each unit of electricity used. YourHome puts heat pumps at about 3 to 5, against about 0.95 for a new electric storage tank and 0.75 to 0.96 for gas (YourHome). Energy NSW says a heat pump can cut hot water energy use by up to 75% (Energy NSW).

Treat brochure COP figures with care. A heat pump works less efficiently as the air gets colder, and makers test their products under different conditions, so two brochures are rarely comparing like with like. YourHome suggests comparing models by the number of STCs each earns in your climate zone on the Clean Energy Regulator’s register, which is a fairer yardstick.

Many heat pumps also have a backup element for very cold mornings or heavy use. If it runs often, the running cost drifts towards that of a plain electric tank, which is one reason sizing the tank properly matters.

The cheapest time to heat is the warm part of the day: the air holds more heat in the afternoon, and if you have rooftop solar, a model with a built-in timer can heat from your own power. Energy NSW recommends a thermostat setting of 60°C.

NOISE AND THE RULES

Where a heat pump can go: the noise rules in NSW

The NSW EPA lists heat pump water heaters among the equipment that should not be heard inside a neighbour’s habitable room before 7am or after 10pm on weekdays, and before 8am or after 10pm on weekends and public holidays (NSW EPA). A habitable room is any room except a garage, storage area, bathroom, laundry, toilet or pantry.

Installed as exempt development, a heat pump must be designed to make no more than 5 dB(A) above the background noise level. On a heritage item or in a heritage conservation area, it must not be on a roof and must be in the rear yard (NSW Planning).

In practice that means placing it away from bedroom windows, yours and the neighbours’, and setting the timer so it heats in the day rather than overnight. On a narrow side passage, a split system with a low outdoor unit is often easier to place than an integrated unit, whose fan sits on top of the tank where, as YourHome notes, the noise can carry over fences.

THE HONEST VIEW

Good to know before you choose

What to know
Running costUses about 30% of the energy of a conventional electric system; usually among the cheapest to run.
Upfront costCosts more to buy than electric or gas, before discounts.
NoiseThe compressor sounds like an air conditioner, so keep it away from bedrooms and neighbours’ windows; councils limit noise at night.
Cold weatherNot all models suit places that regularly drop below 5°C; Sydney’s climate suits most.
Power tariffSome models do not work on controlled load, and some only on Controlled Load 2.
DiscountsEligible models attract the NSW Energy Savings Scheme discount and STCs.

WHO IT SUITS

Is it right for your home?

Replacing electric

The biggest saving, and the biggest NSW discount.

Solar panel homes

Run it in the day from your own solar power.

Long-term owners

A higher upfront price, repaid in lower running costs.

WHAT IT COSTS

Prices in Sydney

Typical Sydney prices, supplied and installed by a licensed plumber. You get a fixed price before any work starts.

SystemInstalled priceNotes
Heat pump, 200 to 340 L$3,800 to $6,650Before NSW discounts and STCs
Electrical work, if neededQuotedA new circuit or changes to the meter board, by an electrician

Typical Sydney market ranges for supply and installation, including GST (1 November 2026). Removal of the old unit is usually included; a tempering valve is about $170 to $460 where needed. Call-out: $0 Monday to Friday, 7:00am to 3:00pm, and Saturday, 7:00am to 12:00pm. Outside those times, and all day on NSW public holidays, the call-out fee is $385 ($350 plus GST), paid before we send a plumber.

DISCOUNTS

Discounts for heat pump and solar hot water

Two schemes cut the price of an eligible heat pump or solar system. The NSW Energy Savings Scheme gives an upfront discount on the quote, which Energy NSW puts at up to $640 when a heat pump replaces an electric system and up to $330 when it replaces gas (Energy NSW), and up to $900 when a solar system replaces electric and up to $550 when it replaces gas (Energy NSW). These figures are indicative, and not every model or home qualifies.

Federal small-scale technology certificates (STCs) also apply to listed heat pumps and solar systems; their number falls each year until the scheme ends in 2030, and they are often already taken off advertised prices (Clean Energy Regulator).

Both are arranged through the installer before the work starts. We take part in the NSW Energy Savings Scheme, so we arrange the discount for you and show it on your written quote. Ask us which models qualify for your home, or read NSW hot water rebates explained.

BRANDS WE INSTALL

Brands we supply and install

We supply and install every heat pump brand Reece sells, including Thermann, Everhot, Rheem, Rinnai and Stiebel Eltron.

To qualify for the NSW discount a heat pump needs at least a 5-year warranty, and better models earn larger discounts. We tell you the warranty and the discount on the exact model before you choose.

INTEGRATED OR SPLIT

Integrated or split, and what the refrigerant means

An integrated heat pump has the compressor and fan on top of the tank, so it connects much like the electric tank it replaces. It can be taller than the old tank, so the height under eaves or inside an enclosure needs checking first.

A split system puts the compressor, fan and coil in a separate outdoor unit, usually no more than 10 to 15 metres from the tank. The tank can stay indoors, the outdoor unit can sit lower and in a warmer spot, and some split units can be paired with an existing tank.

Every heat pump uses a refrigerant. YourHome notes that R290 (propane) and R744 (carbon dioxide) are natural refrigerants with very low global warming potential, while R134A and R513A are HFCs with a far higher one, and the import of HFCs is being phased down. Refrigerant that leaks through poor installation or careless disposal undoes part of the benefit (YourHome).

WARNING SIGNS

Signs a heat pump needs a look

What you noticeWhat it often meansHow urgent
The fan runs but the water stays lukewarmA refrigerant, compressor or sensor fault, or the backup element doing all the workSoon. Check the display for an error code and call us
An error code on the displayThe controller has detected a fault and logged itSoon. Note the code and the model number before you call
Power bills rising for no clear reasonThe backup element running often, a timer reset by a power cut, or a tank too small for the housePlan. Check the settings and the sizing
Louder than it used to be, or rattlingA fan or compressor wearing, or loose mountingsSoon. Extra noise can also become a neighbour problem
Water around the baseCondensation from the coil, which is normal if it drains away, or a leak from the tank or its fittingsCheck. Clear, cool water near the condensate drain is usually normal; water from the tank is not
Ice on the coil that stays all dayMany models clear frost from the coil on their own; ice that lingers points to an airflow or defrost faultCheck. Clear anything blocking the airflow and call if it persists

LOOKING AFTER IT

Keeping a heat pump efficient

  • Keep the area around the outdoor unit clear of leaves, garden growth and stored items, so it can draw air freely (Energy NSW)
  • Make sure the condensate drain is not blocked, so water does not pool around the base
  • Check the timer after a power cut or a change of electricity plan, so it still heats in the warm part of the day
  • Glance at the display now and then: error codes are logged, and they tell us where to start
  • Have the tank’s anode and valves looked after as the owner’s guide sets out, as on any storage tank

ON THE DAY

How a heat pump installation runs

  1. Before the day, we confirm the model, the position and whether your tariff and wiring suit it, and you sign the NSW Energy Savings Scheme nomination form: the discount cannot be claimed for work already done
  2. We drain and remove the old system; under the scheme, it cannot be reused
  3. The heat pump goes on a level base with clear airflow, placed for noise as agreed with you
  4. We connect the water and fit a tempering valve or another approved device, as NSW requires
  5. Any new circuit or switchboard change is done by a licensed electrician
  6. We fill it, power it up and commission it, check the bathroom water is no hotter than 50°C, set the timer with you, and leave the certificates, the warranty details and the scheme paperwork

THE RULES IN NSW

Temperature rules every installation must meet

Storage hot water must be heated to at least 60°C at least once every 7 days, to stop bacteria such as Legionella growing (YourHome).

Water at showers, baths, basins and bidets must be no hotter than 50°C. In NSW a tempering valve or another approved device is required on every new installation and every replacement, including a like-for-like swap (Building Commission NSW). That is why a proper replacement quote includes one, and why faulty tempering valves are among the most common hot water faults in our job records.

FROM OUR JOB RECORDS

What we see on Sydney hot water jobs

Since 2019 our licensed plumbers have completed 1,125 hot water jobs. The most common causes we recorded:

  • Water leak: 60 jobs
  • Faulty tempering valve: 54 jobs
  • Burst water pipe: 40 jobs
  • Faulty hot water element or thermostat: 22 jobs
  • Faulty pressure relief valve: 11 jobs

Half of our priced hot water jobs cost between $495 and $4,015, with a median of $1,980: repairs and replacements together, every type.

QUESTIONS

Questions about heat pump hot water

MORE TYPES

Other hot water systems

READ MORE

Hot water guides

SYDNEY’S 24/7 PLUMBER

Talk to us about your hot water

A licensed plumber will size the right system for your home and give you a fixed price before any work starts.

Licensed NSW 285594C

$0 call-out in business hours

Lifetime labour warranty

4.9 from 3,000+ reviews