Skip to content

Sewer pump station failure: warning signs and an emergency plan

When a sewer pump fails, waste backs up fast. Here are the warning signs, what to do when the alarm sounds, and how to plan for it.

24/7 PRIORITY RESPONSE | WORK ORDERS | COMPLIANCE PACK

Google

Overall Rating

4.9

Five stars

(3,000+)

Brightest & Best Business Awards: Winner 2019, Winner 2024, Winner 2025, People's Choice 2025, Finalist 2023

NOW SERVICING NORTH SYDNEY

  • NSW Contractor Licence 285594C
  • 24/7 Priority Response
  • 5,183 Commercial Jobs Since 2019
  • Report and Photos on Every Job
  • Invoices With Your PO and SP Number
  • Onsite in 30 Minutes Guaranteed

KEY TAKEAWAYS

Quick answer

Reviewed by William Demirdonder, licensed plumber, NSW licence 275278C, on 8 November 2026

  • Building managers
  • Facility managers
  • Strata managers
  • Drains
  • 6 min read

Quick answer

If the pump's high-level alarm sounds, cut water use in the building straight away: no showers, dishwashers or washing machines, and as little flushing as possible. Keep everyone out of the pump well, which is a confined space. Call a plumber; if sewage is backing up it is an emergency. Then plan ahead with a tested alarm, a service schedule, and a standby pump if the building cannot do without one.

  • When the alarm sounds, stop water use first, then call.
  • Never enter the pump well. It is a confined space.
  • Alarms and floats fail silently, so test them.
  • A duty and standby pump gives backup where the building cannot be without one.

GUIDE

Why some buildings rely on pumps

Basements, car parks and some commercial kitchens sit lower than the sewer. Their waste drains into a well, and a pump pushes it up and out to the sewer. When the pump stops, the well fills. Once it is full, waste has nowhere to go but back up through the lowest fixtures and floor wastes.

The property owner is responsible for maintaining the wastewater pipes and fittings on the private side of the connection to Sydney Water's system (Sydney Water Customer Contract). A pump inside a building is usually part of that private system. If you are unsure who owns yours, check your connection agreement.

GUIDE

Warning signs

  • The high-level alarm going off.
  • The pump running constantly, or cycling on and off.
  • Grinding, humming or a new noise.
  • Smells from the pump pit.
  • Slow drains or gurgling in the lowest fixtures.
  • Water pooling around the pit.

GUIDE

Why pumps fail

Wipes, fat and debris jam the impeller. Floats stick, so the pump never starts. Seals and bearings wear. Alarms fail without anyone knowing. In kitchens, fat is the main cause; in basements, silt and debris. A pump with no backup power also stops in a power cut.

CauseEarly signWhat prevents it
Wipes and rags wrapped round the impellerHumming or straining, pump runs longer each cycleSigns in bathrooms, a reminder to residents, regular checks of the well
Fat setting in the wellSmells, a crust on the surface, floats stickingA working grease trap upstream and nothing poured down kitchen sinks
Stuck or tangled floatPump never starts, or never stopsFloats checked and cleaned on a schedule
Worn seals or bearingsNew noise, vibration, tripping the powerServicing to the manufacturer's instructions
Silent alarmNone, which is the problemTesting the alarm, and its battery if it has one

GUIDE

When the alarm sounds

  1. Stop water use. Tell residents or staff not to shower, run dishwashers or washing machines, and to flush as little as possible.
  2. Keep out of the well. SafeWork NSW lists pits, sewers and wet wells among confined spaces, which need a written risk assessment and an entry permit before anyone goes in (SafeWork NSW).
  3. Check for a power cut. Leave any electrical work to a licensed electrician.
  4. Call a plumber. If sewage is backing up, it is a P1 emergency: we are onsite within 30 minutes, 24/7.
  5. Keep people away from any overflow. Sydney Water asks for any wastewater overflow to be reported to its 24/7 faults line on 13 20 90, whether it is on your property or in a public place (Sydney Water: wastewater blockages).
  6. Record it. Note the time, take photos, and list the lots or tenancies affected.

The well is off limits for good reason. SafeWork NSW lists the dangers of confined spaces as loss of consciousness, injury or death from contaminants in the air, suffocation from a lack of oxygen, and fire or explosion. Before anyone enters, a stand-by person must watch conditions from outside, and the air should be tested first (SafeWork NSW: confined spaces). A sewage well can have all three dangers at once.

GUIDE

What to tell the plumber when you call

A clear first call gets the right person, the right gear and sometimes a temporary pump on the first trip. Have these ready:

  • Which pump: its location, and the make and model from the plate or your asset list.
  • What the panel shows: alarm light, fault code, pump running or silent.
  • Whether the power is on to the pump and the rest of the building.
  • Which fixtures are backing up, and whether sewage is escaping anywhere.
  • How the plumber gets in: keys, fobs, car park access and a contact on site.
  • Any recent work nearby, such as a fit-out, a kitchen change or drain clearing.

If sewage is backing up only when water is used in your building, and the neighbours are fine, the fault is likely to be on your side. If it overflows continuously or neighbours have the same problem, Sydney Water says the blockage may be in its pipes, and to call 13 20 90.

GUIDE

After the pump is running again

Getting the pump going is only half the job. Areas reached by sewage need proper cleaning before anyone uses them again, and damaged flooring or stock should be photographed before it is removed, for insurance.

Then find out why it failed. A jammed impeller points to wipes or fat going down the drains, so residents or kitchen staff may need a reminder. A stuck float or a silent alarm means the checks were not working. Ask your plumber for a short report with the cause, what was replaced, and what would stop it happening again.

GUIDE

Plan ahead

  • Know your pumps: make, model, age, and which fixtures drain to each one.
  • Test the alarm and floats with your plumber, so you know they work.
  • Set a service schedule. How often depends on use: a busy kitchen or basement needs more frequent checks than a quiet one.
  • Consider a duty and standby pump if the building cannot be without one.
  • Post the plan on the plant room door, with who to call and where the keys are.

Ask your plumber

When was this alarm last tested, how worn is the pump, and what would a temporary pump cost if it failed tonight?

For a check of your pumps and alarms, see pump stations, or book a free building health check.

DOWNLOAD

Plumbing emergency procedure poster

Free to download and print: Plumbing emergency procedure poster.

QUESTIONS

Questions

SERVICES

How we can help

SOURCES

Sources

Last updated 8 November 2026. General information, not legal advice.

COMMERCIAL & STRATA

Explore Commercial & Strata

KNOWLEDGE CENTRE

Need a hand with this?

Log a job, or start with a free health check of your building.

Planning ahead? Request our compliance pack, book a free building health check or invite us to your contractor panel.

Licensed NSW 285594C

24/7 priority response

Report and photos on every job

4.9 from 3,000+ Google reviews