Sewer pump station failure: warning signs and an emergency plan
When a sewer pump fails, waste backs up fast. Here are the warning signs, what to do when the alarm sounds, and how to plan for it.
24/7 PRIORITY RESPONSE | WORK ORDERS | COMPLIANCE PACK

NOW SERVICING NORTH SYDNEY
WE ARE AVAILABLE
- NSW Contractor Licence 285594C
- 24/7 Priority Response
- 5,183 Commercial Jobs Since 2019
- Report and Photos on Every Job
- Invoices With Your PO and SP Number
- Onsite in 30 Minutes Guaranteed
KEY TAKEAWAYS
Quick answer
Reviewed by William Demirdonder, licensed plumber, NSW licence 275278C, on 8 November 2026
Quick answer
If the pump's high-level alarm sounds, cut water use in the building straight away: no showers, dishwashers or washing machines, and as little flushing as possible. Keep everyone out of the pump well, which is a confined space. Call a plumber; if sewage is backing up it is an emergency. Then plan ahead with a tested alarm, a service schedule, and a standby pump if the building cannot do without one.
- When the alarm sounds, stop water use first, then call.
- Never enter the pump well. It is a confined space.
- Alarms and floats fail silently, so test them.
- A duty and standby pump gives backup where the building cannot be without one.
GUIDE
Why some buildings rely on pumps
Basements, car parks and some commercial kitchens sit lower than the sewer. Their waste drains into a well, and a pump pushes it up and out to the sewer. When the pump stops, the well fills. Once it is full, waste has nowhere to go but back up through the lowest fixtures and floor wastes.
The property owner is responsible for maintaining the wastewater pipes and fittings on the private side of the connection to Sydney Water's system (Sydney Water Customer Contract). A pump inside a building is usually part of that private system. If you are unsure who owns yours, check your connection agreement.
GUIDE
Warning signs
- The high-level alarm going off.
- The pump running constantly, or cycling on and off.
- Grinding, humming or a new noise.
- Smells from the pump pit.
- Slow drains or gurgling in the lowest fixtures.
- Water pooling around the pit.
GUIDE
Why pumps fail
Wipes, fat and debris jam the impeller. Floats stick, so the pump never starts. Seals and bearings wear. Alarms fail without anyone knowing. In kitchens, fat is the main cause; in basements, silt and debris. A pump with no backup power also stops in a power cut.
| Cause | Early sign | What prevents it |
|---|---|---|
| Wipes and rags wrapped round the impeller | Humming or straining, pump runs longer each cycle | Signs in bathrooms, a reminder to residents, regular checks of the well |
| Fat setting in the well | Smells, a crust on the surface, floats sticking | A working grease trap upstream and nothing poured down kitchen sinks |
| Stuck or tangled float | Pump never starts, or never stops | Floats checked and cleaned on a schedule |
| Worn seals or bearings | New noise, vibration, tripping the power | Servicing to the manufacturer's instructions |
| Silent alarm | None, which is the problem | Testing the alarm, and its battery if it has one |
GUIDE
When the alarm sounds
- Stop water use. Tell residents or staff not to shower, run dishwashers or washing machines, and to flush as little as possible.
- Keep out of the well. SafeWork NSW lists pits, sewers and wet wells among confined spaces, which need a written risk assessment and an entry permit before anyone goes in (SafeWork NSW).
- Check for a power cut. Leave any electrical work to a licensed electrician.
- Call a plumber. If sewage is backing up, it is a P1 emergency: we are onsite within 30 minutes, 24/7.
- Keep people away from any overflow. Sydney Water asks for any wastewater overflow to be reported to its 24/7 faults line on 13 20 90, whether it is on your property or in a public place (Sydney Water: wastewater blockages).
- Record it. Note the time, take photos, and list the lots or tenancies affected.
The well is off limits for good reason. SafeWork NSW lists the dangers of confined spaces as loss of consciousness, injury or death from contaminants in the air, suffocation from a lack of oxygen, and fire or explosion. Before anyone enters, a stand-by person must watch conditions from outside, and the air should be tested first (SafeWork NSW: confined spaces). A sewage well can have all three dangers at once.
GUIDE
What to tell the plumber when you call
A clear first call gets the right person, the right gear and sometimes a temporary pump on the first trip. Have these ready:
- Which pump: its location, and the make and model from the plate or your asset list.
- What the panel shows: alarm light, fault code, pump running or silent.
- Whether the power is on to the pump and the rest of the building.
- Which fixtures are backing up, and whether sewage is escaping anywhere.
- How the plumber gets in: keys, fobs, car park access and a contact on site.
- Any recent work nearby, such as a fit-out, a kitchen change or drain clearing.
If sewage is backing up only when water is used in your building, and the neighbours are fine, the fault is likely to be on your side. If it overflows continuously or neighbours have the same problem, Sydney Water says the blockage may be in its pipes, and to call 13 20 90.
GUIDE
After the pump is running again
Getting the pump going is only half the job. Areas reached by sewage need proper cleaning before anyone uses them again, and damaged flooring or stock should be photographed before it is removed, for insurance.
Then find out why it failed. A jammed impeller points to wipes or fat going down the drains, so residents or kitchen staff may need a reminder. A stuck float or a silent alarm means the checks were not working. Ask your plumber for a short report with the cause, what was replaced, and what would stop it happening again.
GUIDE
Plan ahead
- Know your pumps: make, model, age, and which fixtures drain to each one.
- Test the alarm and floats with your plumber, so you know they work.
- Set a service schedule. How often depends on use: a busy kitchen or basement needs more frequent checks than a quiet one.
- Consider a duty and standby pump if the building cannot be without one.
- Post the plan on the plant room door, with who to call and where the keys are.
Ask your plumber
When was this alarm last tested, how worn is the pump, and what would a temporary pump cost if it failed tonight?
For a check of your pumps and alarms, see pump stations, or book a free building health check.
DOWNLOAD
Plumbing emergency procedure poster
Free to download and print: Plumbing emergency procedure poster.
QUESTIONS
Questions
SERVICES
How we can help
SOURCES
Sources
Last updated 8 November 2026. General information, not legal advice.
COMMERCIAL & STRATA
Explore Commercial & Strata
Who we help
Services

KNOWLEDGE CENTRE
Need a hand with this?
Log a job, or start with a free health check of your building.
Planning ahead? Request our compliance pack, book a free building health check or invite us to your contractor panel.
Licensed NSW 285594C
24/7 priority response
Report and photos on every job
4.9 from 3,000+ Google reviews