Skip to content

Medical and Dental Plumbing Contractor Sydney

Backflow, TMVs and hot water done properly, and done after hours, so patients never notice.

24/7 PRIORITY RESPONSE | WORK ORDERS | COMPLIANCE PACK

Google

Overall Rating

4.9

Five stars

(3,000+)

Brightest & Best Business Awards: Winner 2019, Winner 2024, Winner 2025, People's Choice 2025, Finalist 2023

NOW SERVICING NORTH SYDNEY

  • NSW Contractor Licence 285594C
  • 24/7 Priority Response
  • 5,183 Commercial Jobs Since 2019
  • Report and Photos on Every Job
  • Invoices With Your PO and SP Number
  • Onsite in 30 Minutes Guaranteed

THE SHORT ANSWER

In short

Proximity Plumbing looks after the plumbing in medical centres, dental surgeries, physiotherapy and allied health clinics: testable backflow devices tested every 12 months and lodged with Sydney Water, TMVs tested and recorded, hot water, drains and leaks. We work before or after clinic hours where possible, so patients are not disrupted.

WE UNDERSTAND YOUR JOB

What practices tell us

Compliance on time

Backflow tests and TMV records have due dates. Missing one is a problem at audit time.

Patients come first

Noise, water shutdowns and plumbers in the waiting room are not an option during clinic hours.

Hot water that is safe

Hand basins need hot water at a safe temperature, every time.

One call

A leak in a treatment room needs someone there fast, and a report for the practice manager.

HOW WE WORK WITH YOU

How we work with practices

1

Compliance calendar

Backflow and TMV due dates recorded, and visits booked before they fall due.

2

Out of hours

Work booked before opening, after close or on weekends where possible.

3

Clean and quiet

Floors protected and work areas closed off from patients.

4

Records

Test results, certificates and a report for the practice manager.

COMPLIANCE

Backflow, TMVs and hot water in clinics

Testable backflow prevention devices protect the drinking water supply, and Sydney Water requires them to be tested at least once every 12 months by an accredited plumber (Sydney Water). We test the devices, lodge the results and keep your practice on schedule.

Thermostatic mixing valves hold hot water at a safe temperature at hand basins. We test outlet temperatures, service and replace TMVs, and record the results for your audits.

Dental surgeries also need an amalgam trap, with waste amalgam kept separate, under Sydney Water’s trade waste rules (Sydney Water). We install and maintain them.

SAFE HOT WATER

Hot water temperatures at clinic basins

In NSW, the National Construction Code limits heated water at the outlet to 45°C in health-care patient care areas and to 50°C in most other places, achieved to AS/NZS 3500.4 (NCC, NSW). Which limit applies to your rooms depends on how the building is classified; your building certifier can confirm it, and we can measure what each outlet delivers today.

Hospitals, private health facilities and nursing homes also follow NSW Health’s policy, which sets tighter ranges at outlets in patient areas, including consultants’ rooms, treatment areas and clinics within those facilities (NSW Health PD2015_008):

PatientsTemperature at the outletIf the cold supply fails
Adults40.5°C to 45.0°CHot water shuts off, with thermal shut-off at 46.0°C
Children38.0°C to 40.5°CHot water shuts off, with thermal shut-off at 43.5°C

DENTAL SURGERIES

Amalgam traps and dental waste

Sydney Water treats a dental surgery as a deemed trade waste process with a set pre-treatment: an amalgam trap, and waste amalgam kept separate from the wastewater (Sydney Water). A dental technician’s laboratory needs an approved plaster trap instead, while a doctor’s surgery needs no pre-treatment.

The trap only works if it is looked after. Follow the manufacturer’s instructions for emptying or replacing the collection unit, keep the separated amalgam for collection by a waste contractor, and never rinse it down a sink. When chairs are added or moved, the waste lines must still run through the trap.

FIT-OUTS

Planning a new clinic or a refit

  • Hand basins: where they go, and whether they need TMVs to meet the temperature limit that applies
  • Hot water sized for frequent short use all day, with a steady, safe temperature at every basin
  • Backflow: equipment connected to the water supply, such as dental chairs, assessed for the right protection before it is connected
  • Drainage for sterilising and cleaning areas, and floor wastes where wet areas need them
  • For dental surgeries, the amalgam trap, and room to reach its collection unit for service
  • A Notice of Work before larger jobs and a Certificate of Compliance at the end, for your fit-out file

IF IT LEAKS

A leak in a treatment room

  1. Stop using the room, and move patients and equipment away from the water.
  2. Turn off the isolation valve under the basin or on the equipment line, or the main valve if you cannot find one.
  3. Keep water away from power points and electrical equipment.
  4. Take photos before anything is cleaned up.
  5. Call us, and tell us it is a clinic, so we can plan the repair around your patient list.

SERVICES

The services you use most

BUILDING CARE

Planned care for your practice

A Compliance Care Plan books backflow tests and TMV servicing before they fall due, with a report after every visit, so the paperwork is ready when you need it.

YOUR COMMERCIAL TEAM

Who looks after your account

One family business, one commercial team. Every enquiry is answered within 15 minutes, by people you can name.

QUESTIONS

Questions from medical and dental practices

GUIDES

Guides and next steps

COMMERCIAL & STRATA

Explore Commercial & Strata

MEDICAL AND DENTAL

Keep your practice compliant

Book a free health check, or log a job if something needs fixing now.

Planning ahead? Request our compliance pack, book a free building health check or invite us to your contractor panel.

Licensed NSW 285594C

24/7 priority response

Report and photos on every job

4.9 from 3,000+ Google reviews