KEY TAKEAWAYS

Quick answer

Reviewed by William Demirdonder, licensed plumber, NSW licence 275278C, on 8 November 2026

  • Business owners
  • Facility managers
  • Building managers
  • Compliance
  • 6 min read

Quick answer

In NSW, heated water at the outlets children use in an early childhood centre must be no hotter than 45°C, under the National Construction Code's NSW variation, and thermostatic mixing valves (TMVs) usually hold it there. Testable backflow devices are tested every year by an accredited plumber, who sends the results to Sydney Water within 2 days. Regulated plumbing needs a licensed plumber and a Certificate of Compliance. Keep every record in one file.

  • Hot water at outlets children use: no hotter than 45°C.
  • TMVs hold that temperature, and need servicing by a licensed plumber.
  • Testable backflow devices: tested every year, results to Sydney Water within 2 days.
  • Keep certificates, test results and service records together, ready to show.

GUIDE

Hot water: the 45°C rule

The National Construction Code's NSW variation sets the maximum temperature of heated water at sanitary fixture outlets used for personal hygiene. In the parts of an early childhood centre, or a primary or secondary school, that are used by children, it must be no more than 45°C. In other cases the limit is 50°C. The temperature is achieved in line with AS/NZS 3500.4 (ABCB: NCC NSW heated water variation).

In practice that means the basins and showers in children's rooms, bathrooms and nappy change areas. Staff areas may fall under the 50°C limit. Your plumber can map which outlets are which.

GUIDE

TMVs: what they do and how to look after them

A thermostatic mixing valve blends hot and cold water to a set temperature, so the water at the tap stays at or below the limit even when other taps run. A working TMV should also shut off the hot water if the cold supply fails.

  • Have each TMV serviced by a licensed plumber trained in TMVs.
  • Ask your plumber for the servicing interval the valve manufacturer specifies, and put it on a schedule.
  • Ask for a record of each test: the date, the valve, the outlet temperature and any parts replaced.
  • If staff notice water that is too hot or keeps changing temperature, stop using that outlet and call.

Temperature is not the only reason to keep TMVs serviced. NSW Health notes that warm water systems, including TMVs, may allow the growth and transmission of Legionella bacteria (NSW Health: Legionella control). Valves with blocked strainers and outlets that sit unused over long holidays are the ones to watch. After a closure of a week or more, ask your plumber whether the outlets should be flushed before children return.

GUIDE

Backflow testing

A backflow prevention device stops water from your site flowing back into the drinking water supply. Sydney Water requires the owner to have the correct device and keep it in good working order. Testable devices are tested every year by an accredited backflow plumber, who sends the results to Sydney Water within 2 days. If the hazard rating of a site is unknown, Sydney Water treats it as high (Sydney Water: backflow prevention).

If you lease your premises, check your lease to see whether the landlord or your business arranges the test.

GUIDE

Toilets, basins and drains

Children's bathrooms work hard. The common calls we get from early learning centres are blocked toilets, slow basins and floor wastes, and leaking cisterns. Wipes, nappy liners and paper towel are the usual cause of blocked toilets and drains.

  • Keep wipes and liners out of toilets with clear bins and staff reminders.
  • Report slow drains early; a partial block is quicker and cheaper to clear than an overflow.
  • Check under basins for drips during your regular safety checks.

For budgeting, half of our priced commercial and strata blocked toilet jobs since 2019 cost between $418 and $1,320, including GST.

GUIDE

The centre kitchen

Sydney Water's guidance for food businesses says that a business that cooks or serves hot food must have an approved grease trap, installed by a licensed plumber and properly maintained, with the pump-out frequency set by Sydney Water (Sydney Water: food business wastewater). If your centre cooks on site, ask Sydney Water whether your kitchen needs trade waste approval and a trap.

GUIDE

A plumbing calendar for a centre

Most centres already run daily safety checks. Plumbing fits into the same rhythm. This is a suggested routine, not a legal schedule; the manufacturer's instructions and the rules above come first.

How oftenWhatWho
DailyToilets flushing and clearing, no water on bathroom floors, nothing in toilets that should be in the binEducators and cleaners
WeeklyUnder basins and around cisterns for drips, floor wastes draining, any outlet that feels too hot or keeps changingCentre staff, reported to the director
Before each term or after a long closureRun the taps and showers in rooms that were not usedCentre staff, with the plumber's advice
As the manufacturer specifiesTMV servicing and outlet temperature tests, recordedLicensed plumber trained in TMVs
Every yearTestable backflow device tested and results lodgedAccredited backflow plumber
As your agreement setsGrease trap pump-out, if the kitchen has oneWastesafe transporter

Book the plumber's visits for school holidays or before opening, and add the dates to the same calendar as your fire and first aid checks.

Watch out

If your centre leases its premises, check who arranges each item. Leases often split the work: the landlord may own the backflow device and hot water plant, while the centre looks after fixtures inside the rooms.

GUIDE

Keep the paperwork together

Childcare services in NSW are regulated by the NSW Early Learning Commission, which began operating as the independent regulator on 1 December 2025 (NSW Department of Education). Your service's obligations come from the National Law and Regulations; ask the Commission if you are unsure what applies to your premises.

On the plumbing side, keep in one file:

Ask your plumber

Can you list every TMV and backflow device on our site, with its location, last test date and next due date?

We work before or after session times so children are not around tools or isolated water. A free health check is a good first step if you are not sure where your records stand.

DOWNLOAD

Annual strata plumbing compliance calendar

Free to download and print: Annual strata plumbing compliance calendar.

QUESTIONS

Questions

SERVICES

How we can help

SOURCES

Sources

Last updated 8 November 2026. General information, not legal advice.

COMMERCIAL & STRATA

Explore Commercial & Strata