Skip to content

Plumbing and Strata Glossary

Backflow, stacks, SP numbers and more, in plain English.

24/7 PRIORITY RESPONSE | WORK ORDERS | COMPLIANCE PACK

Google

Overall Rating

4.9

Five stars

(3,000+)

Brightest & Best Business Awards: Winner 2019, Winner 2024, Winner 2025, People's Choice 2025, Finalist 2023

NOW SERVICING NORTH SYDNEY

  • NSW Contractor Licence 285594C
  • 24/7 Priority Response
  • 5,183 Commercial Jobs Since 2019
  • Report and Photos on Every Job
  • Invoices With Your PO and SP Number
  • Onsite in 30 Minutes Guaranteed

THE SHORT ANSWER

In short

62 plumbing, drainage and strata terms explained in plain English, from air gap to zone protection. Each term links to the guide or service page that explains it in more detail.

A TO Z

Glossary

Air gap
A physical gap between a water outlet and the highest level water can reach in a fixture or tank, so water can never be drawn back into the supply. One way of protecting a high hazard site from backflow.
Approval limit
The amount a strata manager or building manager can approve for a repair without asking the owners corporation or committee first. Read more
AS/NZS 3500
The Australian and New Zealand plumbing and drainage standard. Plumbing work in NSW must comply with the Plumbing Code of Australia, and AS/NZS 3500 is the usual way to show that it does.
Asset register
A list of a building’s plumbing assets, such as stacks, pumps, hot water plant, backflow devices and TMVs, with their location, age and condition. Read more
Backflow
Water flowing the wrong way, back into the drinking water supply, which can carry contamination with it. Read more
Backflow prevention device
A valve assembly that stops backflow. Testable devices must be tested every year by a backflow-accredited licensed plumber, and the results sent to Sydney Water. Read more
Boundary trap
A water-filled trap near the property boundary that stops sewer gases from the public sewer coming back up the building’s drains. Often used as an access point for clearing and CCTV.
Box gutter
A gutter that sits inside the roof line, between two roof sections or behind a parapet. When it blocks or rusts, water goes into the building. Read more
Break tank
A tank that receives water through an air gap and then supplies the building, keeping the two systems separate. A registered break tank is one way to protect a high hazard site.
Building Care
Proximity Plumbing’s planned plumbing programme for buildings: a free health check, a condition report, a 10-Year Plumbing Plan and Care Plans. Read more
By-laws
The rules of a strata scheme. They can change who is responsible for some repairs, so always check them.
Capital works fund
The fund an NSW owners corporation keeps for major and long-term work on common property. It must have a 10-year capital works plan. It replaced the term sinking fund. Read more
CCTV survey
A camera inspection of a drain or stack, recorded on video, that shows roots, cracks, scale, collapses and blockages without digging. Read more
Certificate of Compliance
The document a licensed plumber or drainer lodges on completion of regulated plumbing and drainage work in NSW, confirming it complies with the rules. A copy goes to whoever arranged the work.
Certificate of compliance (gas)
For gas work connected to the network in NSW, the certificate the gasfitter submits to Building Commission NSW within 5 business days of the work. Read more
Common property
The parts of a strata scheme that are not part of any lot. The owners corporation must repair and maintain common property. Read more
Containment protection
Backflow protection installed at the property boundary, protecting the public water supply from the whole site.
Continuous flow
A water heater that heats water as it flows, with no storage tank. Banks of them can serve a whole building. Read more
Defect coding
A standard way of describing pipe defects found by CCTV. In Australia, asset owners use the WSAA Conduit Inspection Reporting Code (WSA 05). Read more
Downpipe
The vertical pipe that carries rainwater from a gutter down to the stormwater system.
DSR (detailed service report)
A written report after a job: what was reported, what was found, what was done, photos and anything still to fix. Read more
Flow and return
A hot water system that keeps water circulating through a loop of pipes, so hot water reaches far outlets quickly.
Grease trap
A tank that holds back fats, oils and grease from a kitchen’s wastewater before it reaches the sewer. Sydney Water requires one if you cook or serve hot food. Also called a grease arrestor. Read more
Hazard rating
Sydney Water’s rating of how much a site could contaminate the water supply: high, medium or low. It decides which backflow device is needed. Read more
Health check
A licensed plumber’s check of every plumbing asset in a building, rated green, amber or red with photos. Read more
Hydro jetting
Clearing a drain with high-pressure water from a jetter, which cuts through roots, fat and debris.
Individual protection
Backflow protection at a single fixture or appliance.
Inspection opening
A sealed access point in a drain used for clearing and CCTV.
Isolation valve
A valve that shuts off water to part of a building, such as one floor or one lot, so work can be done without turning off the whole building. Read more
JSA
Job safety analysis: a step-by-step list of a task’s hazards and the controls for each. Read more
Lot
An individual unit or property in a strata scheme, owned by a lot owner.
Main valve
The valve, usually at the water meter, that shuts off water to the whole property. Read more
Make-safe
The first work after a plumbing emergency: stopping the water and making the plumbing safe before repairs. Read more
Notice of Work
The notice a licensed plumber or drainer submits before starting regulated plumbing and drainage work in NSW.
Owners corporation
All the lot owners in a strata scheme acting together. It owns and must maintain the common property. Read more
P1 to P4
Proximity Plumbing’s job priorities: P1 emergency, P2 urgent, P3 standard and P4 planned. Read more
Pipe relining
Repairing a pipe from the inside by installing a resin-soaked liner that cures into a new pipe within the old one, without digging or opening walls. Read more
Plant room
The room that houses a building’s pumps, hot water plant, valves and other services. Read more
PO number
Purchase order number: the reference a client gives for a job, which must appear on the invoice so it can be paid. Read more
Pressure reduction valve
A valve that lowers the incoming water pressure to protect pipes and fixtures. Also called a pressure limiting valve.
Rainwater head
A box at the top of a downpipe that collects water from a gutter and often has an overflow.
Relief valve
A safety valve on a hot water system that releases water if temperature or pressure gets too high. A weeping relief valve is a sign of a problem.
Riser
A vertical pipe that carries water, gas or fire service supply up through a building.
RPZD
Reduced pressure zone device: a testable backflow device used where the hazard is high. Read more
Sewer Service Diagram
The plan of a property’s sewer drains. A new one is required on completion of drainage work in NSW.
Sewer surcharge
Sewage backing up and overflowing from a drain, gully or fixture because the line is blocked downstream. A P1 emergency. Read more
Sinking fund
The old name for the capital works fund in NSW strata schemes.
SP number
The strata plan number that identifies a strata scheme. It belongs on every quote, report and invoice.
Stack
A vertical drainage pipe that carries waste from the fixtures on each floor down to the drain. Read more
Stormwater pit
A pit with a grate that collects rainwater from paved areas and roofs and sends it to the stormwater system. Read more
Strata manager
The managing agent an owners corporation appoints to run the scheme day to day, including arranging repairs within its approval limits. Read more
Strata plan
The registered plan that creates a strata scheme and shows the lots and common property.
Sump
A pit that collects water or waste below drain level, usually with a pump to lift it out. Read more
SWMS
Safe work method statement: a document setting out the hazards and controls for high-risk construction work, such as work where a person could fall more than 2 metres. Read more
Tempering valve
A valve that mixes hot and cold water to limit the temperature delivered to bathrooms.
TMV
Thermostatic mixing valve: a valve that holds hot water at a safe temperature at an outlet and shuts off hot water if the cold supply fails. Read more
Trade waste
Wastewater from a business, other than domestic sewage, that goes to the sewer under a Sydney Water approval. Read more
Traffic-light rating
Rating each plumbing asset green (good), amber (plan for it) or red (act now) in a condition report. Read more
Warm water system
A system that delivers water below 60°C to outlets, used in hospitals and aged care. In NSW hospitals it needs written approval from NSW Health.
Water hammer
A banging noise in pipes when a tap or valve shuts quickly, caused by a pressure surge. It can damage pipes and fittings over time.
WaterMark
The Australian certification that plumbing products must carry to be installed.
Zone protection
Backflow protection at the connection to a section of a building’s plumbing system.

COMMERCIAL & STRATA

Explore Commercial & Strata

KNOWLEDGE CENTRE

Still not sure what something means?

Ask us when you log a job: every enquiry is answered within 15 minutes.

Planning ahead? Request our compliance pack, book a free building health check or invite us to your contractor panel.

Licensed NSW 285594C

24/7 priority response

Report and photos on every job

4.9 from 3,000+ Google reviews